Skip to content

General Troubleshooting Steps

Common troubleshooting steps for upgrade and rollback operations.

Check Playbook Logs

Increase Ansible verbosity for detailed output:

Run on: omnia_core container
cd /omnia/upgrade
ansible-playbook upgrade.yml -vvv

Review State Files

All state files are stored in /opt/omnia/.data/:

Run on: omnia_core container
ls -la /opt/omnia/.data/
cat /opt/omnia/.data/upgrade_manifest.yml
cat /opt/omnia/.data/rollback_manifest.yml
cat /opt/omnia/.data/oim_metadata.yml

Check Archived Manifests

Previous manifests are archived for history:

Run on: omnia_core container
ls /opt/omnia/.data/archive/

Reset Upgrade/Rollback State

To completely reset the upgrade/rollback state and start fresh:

Caution

This will discard all upgrade/rollback progress. Use only as a last resort.

Run on: omnia_core container
rm -f /opt/omnia/.data/upgrade_manifest.yml
rm -f /opt/omnia/.data/rollback_manifest.yml
rm -f /opt/omnia/.data/upgrade_in_progress.lock
rm -f /opt/omnia/.data/rollback_in_progress.lock

Verify oim_metadata.yml

The oim_metadata.yml file is the source of truth for version information. Ensure it contains the correct values:

Run on: omnia_core container
cat /opt/omnia/.data/oim_metadata.yml

Expected fields:

  • omnia_version — Currently installed version.
  • previous_omnia_version — Previous version.
  • upgrade_backup_dir — Path to the backup directory.

Note

oim_metadata.yml is read-only for upgrade and rollback flows. It is never modified by the playbooks. If the version information is incorrect, it must be fixed manually before rerunning.