Ensure that PowerCap policy is disabled and the BIOS system profile is set to ‘Performance’ on the OIM.
Always run playbooks inside the Omnia core container from the directory where they are located. Use the
cdcommand to navigate to the playbook’s directory before executing it.If telemetry is enabled, ensure sufficient storage is available in NFS as provided in the
telemetry_config.yml.When using PowerScale as an NFS server, integrate it using the Dell CSI PowerScale driver instead of configuring it as an external NFS server.
Ensure that the external NFS is accessible by all the nodes intended to be booted and is reachable by admin network.
Avoid rebooting the OIM as much as possible to prevent disruptions to the network configuration.
Review all the prerequisites and input files before running Omnia playbooks.
Ensure that the Firefox version being used on the RHEL OIM is the latest available. This can be achieved using
dnf update firefox -yRun
yum update --securityroutinely on the RHEL OIM to get the latest security updates.